All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F25%3A00082422" target="_blank" >RIV/00159816:_____/25:00082422 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216224:14110/25:00142048

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S2212628725001355?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2212628725001355?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.eats.2025.103566" target="_blank" >10.1016/j.eats.2025.103566</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Arthroscopic Transosseous Rotator Cuff Repair Using Bone Tunneling Device

  • Original language description

    Rotator cuff injuries are a common cause of shoulder pain, primarily affecting individuals older than 40 years, with the incidence increasing progressively with age. Advancements in surgical techniques have led to the development of arthroscopic techniques. This evolution has transitioned through various arthroscopic suture anchor rotator cuff repair configurations, including single-row, double-row, and transosseous-equivalent constructs. Although these innovations have replicated the biomechanics of the original transosseous technique conducted using an open approach, they often require multiple anchors, significantly increasing surgical costs. Additionally, anchor-related complications persist. To enhance the feasibility and affordability of implant-free transosseous repair, a reusable instrumentation system, was developed by Drillbone (Brno, Czechia). This innovative device facilitates robust and reproducible transosseous rotator cuff repairs while substantially reducing procedural costs. We present a surgical technique using bone tunneling device, showing its application in arthroscopic rotator cuff repair.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30211 - Orthopaedics

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Arthroscopy Techniques

  • ISSN

    2212-6287

  • e-ISSN

    2212-6287

  • Volume of the periodical

    14

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    8

  • Pages from-to

    nestránkováno

  • UT code for WoS article

    001548196500023

  • EID of the result in the Scopus database