Comparison EUROMET.EM-K8 of DC voltage ratio: results
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F05%3A%230000253" target="_blank" >RIV/00177016:_____/05:#0000253 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Comparison EUROMET.EM-K8 of DC voltage ratio: results
Original language description
A regional key comparison of dc voltage ratio has been carried out in Europe. The method to evaluate the comparison reference value, the resulting degrees of equivalence for the voltage ratios 1000 V/10 V and 100 V/10 V and the link to the correspondingworldwide key comparison CCEM-K8 are reported.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JB - Sensors, detecting elements, measurement and regulation
OECD FORD branch
—
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2005
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
IEEE Transactions on Instrumentation and Measurement
ISSN
0018-9456
e-ISSN
—
Volume of the periodical
54
Issue of the periodical within the volume
2
Country of publishing house
US - UNITED STATES
Number of pages
4
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—