Monte Carlo calculations of calibration and geometry correction factors of a radionuclide calibrator
Result description
The activity of radioactive pharmaceuticals administered to patients in nuclear medicine is usually determined using well-type ionization chamber. A Monte Carlo model was created and basic chamber characteristics were calculated and compared with experimental measurements. The chamber response for various ampoules was also studied.
Keywords
The result's identifiers
Result code in IS VaVaI
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Monte Carlo calculations of calibration and geometry correction factors of a radionuclide calibrator
Original language description
The activity of radioactive pharmaceuticals administered to patients in nuclear medicine is usually determined using well-type ionization chamber. A Monte Carlo model was created and basic chamber characteristics were calculated and compared with experimental measurements. The chamber response for various ampoules was also studied.
Czech name
—
Czech description
—
Classification
Type
Jx - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2006
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Volume of the periodical
68
Issue of the periodical within the volume
7-8
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—
Result type
Jx - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP
BG - Nuclear, atomic and molecular physics, accelerators
Year of implementation