Applications of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by ~1 MJ plasma focus
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F10%3A%230000201" target="_blank" >RIV/00177016:_____/10:#0000201 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Applications of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by ~1 MJ plasma focus
Original language description
The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of 1 MJ, was measured using a Bonner spheres spectrometer (BSS) in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BF - Elementary particle theory and high energy physics
OECD FORD branch
—
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Volume of the periodical
81
Issue of the periodical within the volume
1
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—