Negative gauge pressure comparison: range -95 kPa to 95 kPa (EURAMET Project 1131).

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F10%3A%230000378" target="_blank" >RIV/00177016:_____/10:#0000378 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Negative gauge pressure comparison: range -95 kPa to 95 kPa (EURAMET Project 1131).

  • Original language description

    A pressure comparison in the negative gauge pressure range was arranged in 2009. The participating laboratories were CMI/Czech Republic, FORCE Technology/Denmark, AS Metrosert/Estonia and MIKES/Finland. Negative gauge pressures are a common range for pressure calibrations although uncertainty requirements are generally not very high. The results from the four participating laboratories suggest that calibrations in the negative gauge pressure range are not as easy as expected. Some of the claimed uncertainties were perhaps too optimistic, and the large variation in the results made it difficult to generate consistent reference values. The agreement of the results at positive gauge pressures on the same transfer standard was much better. Obviously thereis a need for further comparisons in the negative gauge pressure range. The transfer standard was a multifunction calibrator Beamex MC5 equipped with an internal pressure module for the range - 100 kPa to 104 kPa in the gauge mode. The re

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JB - Sensors, detecting elements, measurement and regulation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2010

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Metrologia

  • ISSN

    0026-1394

  • e-ISSN

  • Volume of the periodical

    47

  • Issue of the periodical within the volume

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    10

  • Pages from-to

    1-10

  • UT code for WoS article

  • EID of the result in the Scopus database