Phase Comparison of High-Current Shunts up to 100 kHz
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F11%3A%230000363" target="_blank" >RIV/00177016:_____/11:#0000363 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Phase Comparison of High-Current Shunts up to 100 kHz
Original language description
A comparison of the phase error of existing shunts for currents between 10 and 100 A and frequencies from 500 Hz to 100 kHz has been organized. Measurement processes were performed at Istituto Nationale di Ricerca Metrologica on some shunts using the first prototype of a new type of a phase comparator and a step-up method for data processing. Results of the relative measurement processes have shown good repeatability. The method for evaluation of reference values was based on similar shunts and suitableassumptions and derived by extrapolation. For the type of resistance elements employed in these shunts, the derivation of the reference is not very accurate and still needs to be improved.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JB - Sensors, detecting elements, measurement and regulation
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
IEEE Transactions on Instrumentation and Measurement
ISSN
0018-9456
e-ISSN
—
Volume of the periodical
2011
Issue of the periodical within the volume
60
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
2359-2365
UT code for WoS article
—
EID of the result in the Scopus database
—