Low optical power reference detector implemented in the validation of two independent techniques for calibrating photon-counting detectors
Result description
We introduce a technique for measuring detection efficiency that is traceable to the primary standard, the cryogenic radiometer, through a reference silicon photodiode trap detector. The trap detector, used in conjunction with a switched integrator amplifier, can measure signals down to the 0.1 pW (3 x 10^5 photons second-1) level with 0.1% uncertainty in a total integration time of 300 seconds. This provides a convenient calibration standard for measurements at these levels across the optical spectrum(UV - near IR). A second technique is also described, based on correlated photons produced via parametric down-conversion. This can be used to directly measure detection efficiency in the photon counting regime, and provides a route for expanding the formulation of the candela in terms of photon flux to enable it to address the needs of emerging quantum optical technologies and applications. The two independent techniques were cross-validated by a comparison carried out at 702.2 nm, whic
Keywords
The result's identifiers
Result code in IS VaVaI
Result on the web
DOI - Digital Object Identifier
Alternative languages
Result language
angličtina
Original language name
Low optical power reference detector implemented in the validation of two independent techniques for calibrating photon-counting detectors
Original language description
We introduce a technique for measuring detection efficiency that is traceable to the primary standard, the cryogenic radiometer, through a reference silicon photodiode trap detector. The trap detector, used in conjunction with a switched integrator amplifier, can measure signals down to the 0.1 pW (3 x 10^5 photons second-1) level with 0.1% uncertainty in a total integration time of 300 seconds. This provides a convenient calibration standard for measurements at these levels across the optical spectrum(UV - near IR). A second technique is also described, based on correlated photons produced via parametric down-conversion. This can be used to directly measure detection efficiency in the photon counting regime, and provides a route for expanding the formulation of the candela in terms of photon flux to enable it to address the needs of emerging quantum optical technologies and applications. The two independent techniques were cross-validated by a comparison carried out at 702.2 nm, whic
Czech name
—
Czech description
—
Classification
Type
Jx - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BH - Optics, masers and lasers
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Optics Express
ISSN
1094-4087
e-ISSN
—
Volume of the periodical
2011 Oct
Issue of the periodical within the volume
10
Country of publishing house
US - UNITED STATES
Number of pages
16
Pages from-to
20347-63