Cavitation of LNG in ultrasonic flowmeters - CFD modelling
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F13%3A%230000830" target="_blank" >RIV/00177016:_____/13:#0000830 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Cavitation of LNG in ultrasonic flowmeters - CFD modelling
Original language description
In this paper a possible cavitation of LNG in ultrasonic flowmeters is investigated. The cavitation is an unwanted effect which can occur especially near the ultrasound transducer mountings where sharp edges at the wall can appear. By means of numericalmodelling we predict pressure drops which can occur near the pockets in front of the ultrasound transducers. We then calculate a minimal sub-cooling of LNG below the bubble point temperature for which the cavitation can be avoided for various velocitiesand pressures in the fluid.