Assessment of Radiochromic Gel Dosimeter Based on Turnbull blue dye for Relative Output Factor Measurements in Small Radiosurgery Fields of the Leksell Gamma Knife Perfexion
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F15%3A%230001099" target="_blank" >RIV/00177016:_____/15:#0001099 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/article/10.1088/1742-6596/573/1/012049" target="_blank" >http://iopscience.iop.org/article/10.1088/1742-6596/573/1/012049</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/573/1/012049" target="_blank" >10.1088/1742-6596/573/1/012049</a>
Alternative languages
Result language
angličtina
Original language name
Assessment of Radiochromic Gel Dosimeter Based on Turnbull blue dye for Relative Output Factor Measurements in Small Radiosurgery Fields of the Leksell Gamma Knife Perfexion
Original language description
The aim of the study was to perform assessment of radiochromic gel dosimeter based on Turnbull blue dye formed by irradiation for measurement of ROFs for 4 mm and 8 mm collimators for the Leksell Gamma Knife PerfexionTM. All measurements have been carried out using home-made spherical Perspex glass phantom of diameter 160 mm. TB gel dosimeters were scanned using homemade optical CT scanner. The results are compared with vendor recommended Monte Carlo calculated ROFs values of 0.814 and 0.900 for 4 mm and 8 mm collimators, respectively. The comparisons between the gel measurements and the treatment planning system (TPS) calculation are presented in the form of 2D isodoses for the central slices and 1D profile. Calculated ROF 0.874 and 0.746 for 8 mm and4 mm collimator respectively are in good agreement with vendor recommended values and measured relative dose distribution in central slice and measured profiles of all shots show excellent correspondence with TPS.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Physics: Conference Series
ISSN
1742-6596
e-ISSN
—
Volume of the periodical
573
Issue of the periodical within the volume
1
Country of publishing house
US - UNITED STATES
Number of pages
4
Pages from-to
1-4
UT code for WoS article
—
EID of the result in the Scopus database
—