Validation of Monte Carlo model of HPGe detector for field-station measurement of airborne radioactivity
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F16%3A%230001106" target="_blank" >RIV/00177016:_____/16:#0001106 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/article/10.1088/1748-0221/11/03/P03015" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/11/03/P03015</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/11/03/P03015" target="_blank" >10.1088/1748-0221/11/03/P03015</a>
Alternative languages
Result language
angličtina
Original language name
Validation of Monte Carlo model of HPGe detector for field-station measurement of airborne radioactivity
Original language description
A Monte Carlo (MC) model of a mechanically-cooled High Purity Germanium detection system IDM-200-V manufactured by ORTEC was created, optimized and validated within the scope of the Joint Research Project ENV57 "Metrology for radiological early warning networks in Europe''. The validation was performed for a planar source homogeneously distributed on a filter placed on top of the detector end cap and for point sources positioned farther from the detector by comparing simulated full-energy peak (FEP) detection efficiencies with the ones measured with two or three different pieces of the IDM detector. True coincidence summing correction factors were applied to the measured FEP efficiencies. Relative differences of FEP efficiencies laid within 8% that isfully satisfactory for the intended use of the detectors as instruments for airborne radioactivity measurement in field-stations. The validated MC model of the IDM-200-V detector is now available for further MC calculations planned in the
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/7AX15014" target="_blank" >7AX15014: Metrology for radiological early warning networks in Europe</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Volume of the periodical
11
Issue of the periodical within the volume
March 2016
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
1-10
UT code for WoS article
—
EID of the result in the Scopus database
—