All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Measurement of gauge blocks by interferometry

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F16%3A%230001221" target="_blank" >RIV/00177016:_____/16:#0001221 - isvavai.cz</a>

  • Result on the web

    <a href="http://stacks.iop.org/0026-1394/53/i=1A/a=04003?key=crossref.610b986750827900c0c10edf8d79e5a8" target="_blank" >http://stacks.iop.org/0026-1394/53/i=1A/a=04003?key=crossref.610b986750827900c0c10edf8d79e5a8</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/0026-1394/53/1A/04003" target="_blank" >10.1088/0026-1394/53/1A/04003</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Measurement of gauge blocks by interferometry

  • Original language description

    The metrological equivalence of national measurement standards will be determined by a set of key comparisons chosen and organized by the Consultative Committees of the CIPM working closely with the Regional Metrology Organizations (RMOs). At its meetingin September 2008, the Consultative Committee for Length, CCL, identified several key comparisons in the field of dimensional metrology. In particular, it decided that the formally individual key comparisons on short gauge blocks and on length bars (long gauge blocks) should be combined under the designation CCL-K1. The key comparison detailed in this document, EURAMET.L-K1.2011, is parallel to the CIPM key comparison CCL-K1.2011 which is piloted by CENAM and NRC. Key Comparison EURAMET.L-K1 was instigated following a decision at the 2010 meeting of the EURAMET Length contact persons held at SP Technical Research Institute of Sweden. The sets of gauge blocks used in both the CCL and EURAMET key comparisons have almost the same composit

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JB - Sensors, detecting elements, measurement and regulation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Metrologia

  • ISSN

    0026-1394

  • e-ISSN

  • Volume of the periodical

    53

  • Issue of the periodical within the volume

    1A

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    63

  • Pages from-to

    1-63

  • UT code for WoS article

  • EID of the result in the Scopus database