All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Characterization of the Graphite Moderated Thermal Neutron Field at CMI

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F17%3AN0000054" target="_blank" >RIV/00177016:_____/17:N0000054 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1093/rpd/ncx190" target="_blank" >https://doi.org/10.1093/rpd/ncx190</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncx190" target="_blank" >10.1093/rpd/ncx190</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Characterization of the Graphite Moderated Thermal Neutron Field at CMI

  • Original language description

    The graphite pile was set up at CMI to provide reference thermal neutron field for metrology and dosimetry purposes. It consists of three Pu–Be and three Am–Be radionuclide sources located in a 1.95 m (width) × 1.95 m (length) × 2.0m (height) graphite moderator block. The neutron field in the volume of the experimental channel with dimensions of 40 cm × 40 cm × 135 cm (depth) was characterised experimentally and by Monte-Carlo calculations. Neutron fluence was determined by the activation of gold foils and Manganese tablets irradiated in nine different positions and by two 3He detectors of different construction irradiated in one position (bare and covered in three spherical PE moderators of 3, 3.5 and 4 inch diameter). Weighted mean value of the neutron fluence rate measured by all the abovementioned detectors in the pile centre was used as a calibration factor for the Monte-Carlo model predictions. The neutron spectral fluence rate calculated by validated Monte-Carlo model was used to determine the conventionally true ambient and personal dose equivalent rates at different positions.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>ost</sub> - Miscellaneous article in a specialist periodical

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

    1742-3406

  • Volume of the periodical

    "neuveden"

  • Issue of the periodical within the volume

    September 2017

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    3

  • Pages from-to

    "nestrankovano"

  • UT code for WoS article

  • EID of the result in the Scopus database