All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Four Terminal Pair Digital Sampling Impedance Bridge up to 1 MHz

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F19%3AN0000006" target="_blank" >RIV/00177016:_____/19:N0000006 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/8678856" target="_blank" >https://ieeexplore.ieee.org/document/8678856</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/TIM.2019.2908649" target="_blank" >10.1109/TIM.2019.2908649</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Four Terminal Pair Digital Sampling Impedance Bridge up to 1 MHz

  • Original language description

    This paper describes a new four terminal pair digital sampling impedance bridge designed for frequency range up to 1MHz and small impedances, such as shunts. The bridge is capable of comparing impedance standards of arbitrary ratios in a full complex plane from approximately 100 kΩ down to 50mΩ, limited by maximum achievable current 3 A. To keep low uncertainties a new multiplexer was designed and a very simple and fully automated linearity correction method based on the pair of calculable resistors was developed and validated. The paper describes the design and details of the bridge topology, basic uncertainty budget and first results of the validation. The expanded uncertainty of impedance module is about 50 μΩ/Ω at 1MHz for impedance ratios up to 1:16 and voltage drops above 10mV and the expanded uncertainty of a phase angle was about 360 μrad/MHz. Expanded uncertainty for frequency 100 kHz about 10 μΩ/Ω was reached. Typical expanded uncertainty for low impedance ratios below 1:1.1 is only 35 μΩ/Ω. Set of measurement of impedance standards of known values and a small international comparison of ac-dc and phase angle errors of current shunts were carried out to validate the bridge capabilities in wide range of impedances. The validation measurements showed the deviations of the bridge are below 35 μΩ/Ω and below 350 μrad at 1 MHz.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>ost</sub> - Miscellaneous article in a specialist periodical

  • CEP classification

  • OECD FORD branch

    20205 - Automation and control systems

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    IEEE Transactions on Instrumentation and Measurement

  • ISSN

    0018-9456

  • e-ISSN

  • Volume of the periodical

  • Issue of the periodical within the volume

    2019

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    10

  • Pages from-to

    1-10

  • UT code for WoS article

  • EID of the result in the Scopus database