Best method for the calibration of pulse generators
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F19%3AN0000089" target="_blank" >RIV/00177016:_____/19:N0000089 - isvavai.cz</a>
Result on the web
<a href="http://rfmw.cmi.cz/index.php/download/54-bpguides.html" target="_blank" >http://rfmw.cmi.cz/index.php/download/54-bpguides.html</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Best method for the calibration of pulse generators
Original language description
This guide summarizes various methods for calibration of pulse generators, which are used for calibration of EMI receivers and spectrum analyzers with quasipeak (QP) detector. Measurement receivers with quasipeak (QP) detector are mainly discussed in European CISPR documents (CISPR – Comité International Spécial des Perturbations Rádioélectriques) and US standards ANSI 63.2 (QP parts derived from CISPR). In the last years, standards are being harmonized (international and national standards committees) and updated to reflect the current status of technology. The calibration of pulse generators is discussed in the standard EN 55016-1-1, which is the harmonized version of the international standard IEC/CISPR 16-1-1. Annex B of CISPR 16-1-1 discusses the determination of pulse generator spectrum and Annex C discusses accurate measurements of the output of nanosecond pulse generators. In the standard, only a very brief description of the methods is given, and technical details are hidden. The measurement uncertainty of the pulse generator characterization is not discussed. The guide provides a brief overview of pulse generators principles and then several methods for spectrum amplitude determination are provided together with the measurement uncertainty.
Czech name
—
Czech description
—
Classification
Type
V<sub>souhrn</sub> - Summary research report
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/8B16005" target="_blank" >8B16005: Development of RF and microwave metrology capability</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Number of pages
23
Place of publication
Praha, Česká republika
Publisher/client name
EURAMET
Version
—