Measurement of the branching ratio related to the internal pair production of Y-90
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F20%3AN0000001" target="_blank" >RIV/00177016:_____/20:N0000001 - isvavai.cz</a>
Alternative codes found
RIV/00177016:_____/20:N0000022
Result on the web
<a href="https://doi.org/10.1016/j.apradiso.2019.108942" target="_blank" >https://doi.org/10.1016/j.apradiso.2019.108942</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2019.108942" target="_blank" >10.1016/j.apradiso.2019.108942</a>
Alternative languages
Result language
angličtina
Original language name
Measurement of the branching ratio related to the internal pair production of Y-90
Original language description
The aim of the work is to determine the number of positron-electron pair creation in the E0 transition between the 1760.7 keV level and the ground level of the Zr-90 nucleus at the Y-90 decay. The number of conversions is determined from the number of 511 keV photons originating from positron annihilation corrected for the annihilation of positrons in flight. Emission of annihilation photons was determined from the measurements of 511 keV full-energy peak on two calibrated high-purity germanium detectors. The measurements were performed with two sources of a different construction. The first source was a 1 ml ampoule filled with Sr-90 solution (in equilibrium with Y-90) with an activity of 38.041 MBq inserted into an aluminum absorber. The other source was the evaporation residue of the Sr-90 solution (in equilibrium with Y-90) in a polyethylene absorber. In both cases, the annihilation of positrons occurred in the source materials. The efficiency of 511 keV photon detection was determined by Monte Carlo calculation, where the source was defined as a theoretical continuous positron spectrum with a maximum energy of 738 keV. The branching ratio related to the internal pair production during Y-90 decay was determined to be (3.26 ± 0.04) × 10-5 pairs/decay.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Result continuities
Project
<a href="/en/project/8B16002" target="_blank" >8B16002: Metrology for clinical implementation of dosimetry in molecular radiotherapy</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Volume of the periodical
156
Issue of the periodical within the volume
156
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
5
Pages from-to
108942
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85073193779