Round robin comparison on quantitative nanometer scale magnetic field measurements by magnetic force microscopy
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F20%3AN0000028" target="_blank" >RIV/00177016:_____/20:N0000028 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14740/20:00118348
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0304885320300366" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0304885320300366</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmmm.2020.166947" target="_blank" >10.1016/j.jmmm.2020.166947</a>
Alternative languages
Result language
angličtina
Original language name
Round robin comparison on quantitative nanometer scale magnetic field measurements by magnetic force microscopy
Original language description
Magnetic force microscopy (MFM) can be considered as a standard tool for nano-scale investigation of magnetic domain structures by probing the local stray magnetic field landscape of the measured sample. However, this generally provides only qualitative data. To quantify the stray magnetic fields, the MFM system must be calibrated. To that end, a transfer function (TF) approach was proposed, that, unlike point probe models, fully considers the finite extent of the MFM tip. However, albeit being comprehensive, the TF approach is not yet well established, mainly due to the ambiguities concerning the input parameters and the measurement procedure. Additionally, the calibration process represents an ill-posed problem which requires a regularization that introduces further parameters. In this paper we propose a guideline for quantitative stray field measurements by standard MFM tools in ambient conditions. All steps of the measurement and calibration procedure are detailed, including reference sample and sample under test (SUT) measurements and the data analysis. The suitability of the reference sample used in the present work for calibrated measurements on a sub-micron scale is discussed. A specific regularization approach based on a Pseudo-Wiener Filter is applied and combined with criteria for the numerical determination of a unique regularization parameter. To demonstrate the robustness of such a defined approach, a round robin comparison of magnetic field measurements was conducted by four laboratories. The guideline, the reference sample and the results of the round robin are discussed.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
21002 - Nano-processes (applications on nano-scale); (biomaterials to be 2.9)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Magnetism and Magnetic Materials
ISSN
0304-8853
e-ISSN
—
Volume of the periodical
511
Issue of the periodical within the volume
166947
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
11
Pages from-to
1-11
UT code for WoS article
000544879400010
EID of the result in the Scopus database
—