D3: Summary report on the uncertainty budget of the digital bridges for the capacitance range from 10 pF to 10 nF at frequencies up to 100 kHz developed and characterised with a target uncertainty: 10-5 at 100 kHz and 5∙10-8 at 1 kHz and 2∙10-7 at 1541 Hz.

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F22%3AN0000071" target="_blank" >RIV/00177016:_____/22:N0000071 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    D3: Summary report on the uncertainty budget of the digital bridges for the capacitance range from 10 pF to 10 nF at frequencies up to 100 kHz developed and characterised with a target uncertainty: 10-5 at 100 kHz and 5∙10-8 at 1 kHz and 2∙10-7 at 1541 Hz.

  • Original language description

    Summary report on the uncertainty budget of the digital bridges for the capacitance range from 10 pF to 10 nF at frequencies up to 100 kHz developed and characterised with a target uncertainty: 10-5 at 100 kHz and 5∙10-8 at 1 kHz and 2∙10-7 at 1541 Hz. The report is deliverable D3 of the project and summarises outputs of activities A2.1.1 and A2.1.2 performed within Task 2.1, Digital bridges. This task aimed to extend the frequency range of digital bridges up to 100 kHz whilst maintaining their uncertainties at the level necessary for primary metrology (10-5 to below 10-7, depending on the applied equipment and frequency). Several systematic errors follow the square of the frequency. The hardware at most primary laboratories, which were focused mainly on maintaining traceability up to a few kHz or 20 kHz at most, was limited for application in the audio frequency range. Another approach was developing fully digital bridges for tracing capacitance unit from resistors with calculable frequency dependence, later replaced by QHR within WP3. Such development has to be followed with validation and evaluation of uncertainty budgets. This report describes the uncertainty budgets of bridges involved within Task 2.1

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/8B19009" target="_blank" >8B19009: Graphene impedance quantum standard</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů