All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Final publishable report from 18HLT04 UHDpulse

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F23%3AN0000077" target="_blank" >RIV/00177016:_____/23:N0000077 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Final publishable report from 18HLT04 UHDpulse

  • Original language description

    Příspěvek ČMI: plnění pracovních povinností daných protokolem projektu In vivo radiobiological experiments have shown that irradiation with electron beams and ultra-high doses per pulse leads to a dramatic reduction of adverse side effects. However, pulses with dose rates higher than conventional radiotherapy present significant metrological challenges. Most of the dosimetry detection systems used in electron and proton therapy beam monitoring, quality assurance, and commissioning had shown saturation effects or were unable to detect the entire radiation dose in such a short time of ultra-high dose delivery. The project investigated several technological challenges and state-of-the-art ideas for detector development, calibrations, and a metrological framework for traceable absorbed dose measurements. As a result, this project established metrology standards, traceability methods, and the development of new detection systems for beam monitoring and field characterisation. This includes i) a robust metrological framework, establishing SI-traceable primary and secondary reference standards and validated methods for dosimetry measurements in particle beams with ultra-high pulse dose rates, ii) characterised the response of available detector systems, iii) developed traceable and validated methods for relative dosimetry and characterisation of stray radiation outside the primary pulsed particle beams, ensuring safer and more effective treatments, and iv) provided essential input data for Codes of Practice for absolute dose measurements. Overall, the project's achievements significantly enhanced the accuracy and reliability of dosimetry in ultra-high dose rate treatment techniques, empowering medical professionals and researchers to deliver more effective and safer radiotherapy. The project's outcomes have directly addressed the user's needs, enabling improved treatment, quality assurance, and commissioning in pre-clinical, clinical and research laboratories

  • Czech name

  • Czech description

Classification

  • Type

    V<sub>souhrn</sub> - Summary research report

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

    <a href="/en/project/8B19001" target="_blank" >8B19001: Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Number of pages

    19

  • Place of publication

    PTB Branschweig, Německo

  • Publisher/client name

    EURAMET

  • Version