Thermal neutron detection and track recognition method in reference and out-of-field radiotherapy FLASH electron fields using Timepix3 detectors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F23%3AN0000088" target="_blank" >RIV/00177016:_____/23:N0000088 - isvavai.cz</a>
Result on the web
<a href="https://iopscience.iop.org/article/10.1088/1361-6560/acf2e1" target="_blank" >https://iopscience.iop.org/article/10.1088/1361-6560/acf2e1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1361-6560/acf2e1" target="_blank" >10.1088/1361-6560/acf2e1</a>
Alternative languages
Result language
angličtina
Original language name
Thermal neutron detection and track recognition method in reference and out-of-field radiotherapy FLASH electron fields using Timepix3 detectors
Original language description
The work presents a method for enhanced detection, imaging, and measurement of the thermal neutron flux. Approach. Measurements were performed in a water tank, while the detector is positioned out-of-field of a 20 MeV ultra-high pulse dose rate electron beam. A semiconductor pixel detector Timepix3 with a silicon sensor partially covered by a 6LiF neutron converter was used to measure the flux, spatial, and time characteristics of the neutron field. To provide absolute measurements of thermal neutron flux, the detection efficiency calibration of the detectors was performed in a reference thermal neutron field. Neutron signals are recognized and discriminated against other particles such as gamma rays and x-rays. This is achieved by the resolving power of the pixel detector using machine learning algorithms and high-resolution pattern recognition analysis of the high-energy tracks created by thermal neutron interactions in the converter. Main results. The resulting thermal neutrons equivalent dose was obtained using conversion factor (2.13(10) pSv·cm2) from thermal neutron fluence to thermal neutron equivalent dose obtained by Monte Carlo simulations. The calibrated detectors were used to characterize scattered radiation created by electron beams. The results at 12.0 cm depth in the beam axis inside of the water for a delivered dose per pulse of 1.85 Gy (pulse length of 2.4 μs) at the reference depth, showed a contribution of flux of 4.07(8) × 103 particles·cm−2·s−1 and equivalent dose of 1.73(3) nSv per pulse, which is lower by ∼9 orders of magnitude than the delivered dose. Significance. The presented methodology for in-water measurements and identification of characteristic thermal neutrons tracks serves for the selective quantification of equivalent dose made by thermal neutrons in out-of-field particle therapy.
Czech name
—
Czech description
—
Classification
Type
J<sub>ost</sub> - Miscellaneous article in a specialist periodical
CEP classification
—
OECD FORD branch
10304 - Nuclear physics
Result continuities
Project
<a href="/en/project/8B19001" target="_blank" >8B19001: Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physics in Medicine & Biology
ISSN
0031-9155
e-ISSN
1361-6560
Volume of the periodical
68
Issue of the periodical within the volume
18
Country of publishing house
GB - UNITED KINGDOM
Number of pages
17