Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F25%3AN0000107" target="_blank" >RIV/00177016:_____/25:N0000107 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1088/1748-0221/20/02/P02012" target="_blank" >https://doi.org/10.1088/1748-0221/20/02/P02012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/20/02/P02012" target="_blank" >10.1088/1748-0221/20/02/P02012</a>
Alternative languages
Result language
angličtina
Original language name
Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute
Original language description
The paper describes the measurement geometry and summarizes the improvement in the setup and methods used at Czech Metrology Institute for the spectrometry of X-ray beams with cadmium telluride X-123CdTe detector. The front, lateral, and rear shielding of the detector was enlarged and sources of parasitic contribution to the characteristic peaks in the measured spectrum were supressed. Methodology for an accurate positioning of the detector towards the focus point was improved with a tool allowing to visualize projections of two pinholes using a pixel detector. The estimated uncertainty of the alignment was 0.2◦. The tilt of the aperture axis of tungsten collimation disks with 50 μm and 100 μm aperture diameters, which caused distortion of measured spectra, was determined allowing, together with the improved methodology for the detector alignment, to use these disks in the same way as the other collimation disks with larger aperture diameters. As a result, the range of measurable photon flux was increased roughly by a factor of 19. The instrumentation and methods adopted and optimized at CMI allow to perform mobile in-beam X-ray spectrometry up to 300 kV in laboratory and clinical conditions with the range of collimation disks of nominal aperture diameters starting from 50 μm.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JOURNAL OF INSTRUMENTATION
ISSN
—
e-ISSN
1748-0221
Volume of the periodical
20
Issue of the periodical within the volume
2
Country of publishing house
GB - UNITED KINGDOM
Number of pages
32
Pages from-to
—
UT code for WoS article
001434679100001