Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F25%3AN0000107" target="_blank" >RIV/00177016:_____/25:N0000107 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1088/1748-0221/20/02/P02012" target="_blank" >https://doi.org/10.1088/1748-0221/20/02/P02012</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/20/02/P02012" target="_blank" >10.1088/1748-0221/20/02/P02012</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Improved setup and characterization of cadmium telluride detector for in-beam X-ray spectrometry up to 300 kV at Czech Metrology Institute

  • Original language description

    The paper describes the measurement geometry and summarizes the improvement in the setup and methods used at Czech Metrology Institute for the spectrometry of X-ray beams with cadmium telluride X-123CdTe detector. The front, lateral, and rear shielding of the detector was enlarged and sources of parasitic contribution to the characteristic peaks in the measured spectrum were supressed. Methodology for an accurate positioning of the detector towards the focus point was improved with a tool allowing to visualize projections of two pinholes using a pixel detector. The estimated uncertainty of the alignment was 0.2◦. The tilt of the aperture axis of tungsten collimation disks with 50 μm and 100 μm aperture diameters, which caused distortion of measured spectra, was determined allowing, together with the improved methodology for the detector alignment, to use these disks in the same way as the other collimation disks with larger aperture diameters. As a result, the range of measurable photon flux was increased roughly by a factor of 19. The instrumentation and methods adopted and optimized at CMI allow to perform mobile in-beam X-ray spectrometry up to 300 kV in laboratory and clinical conditions with the range of collimation disks of nominal aperture diameters starting from 50 μm.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    JOURNAL OF INSTRUMENTATION

  • ISSN

  • e-ISSN

    1748-0221

  • Volume of the periodical

    20

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    32

  • Pages from-to

  • UT code for WoS article

    001434679100001

  • EID of the result in the Scopus database