Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F12%3A10123857" target="_blank" >RIV/00179906:_____/12:10123857 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/12:10123857
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S1507136712000478" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1507136712000478</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.rpor.2012.03.003" target="_blank" >10.1016/j.rpor.2012.03.003</a>
Alternative languages
Result language
angličtina
Original language name
Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment
Original language description
To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of conebeam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. In 12 % of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5patients. Coverage of seminal vesicles was not satisfactory in 3 % of plans. Most of the target underdosage corresponded to excessive rectal of bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22 % and 11 % of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety ma
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FD - Oncology and haematology
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Reports of Practical Oncology and Radiotherapy
ISSN
1507-1367
e-ISSN
—
Volume of the periodical
17
Issue of the periodical within the volume
3
Country of publishing house
PL - POLAND
Number of pages
7
Pages from-to
134-140
UT code for WoS article
—
EID of the result in the Scopus database
—