Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F12%3A10123857" target="_blank" >RIV/00179906:_____/12:10123857 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11150/12:10123857

  • Result on the web

    <a href="http://www.sciencedirect.com/science/article/pii/S1507136712000478" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1507136712000478</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.rpor.2012.03.003" target="_blank" >10.1016/j.rpor.2012.03.003</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment

  • Original language description

    To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of conebeam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. In 12 % of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5patients. Coverage of seminal vesicles was not satisfactory in 3 % of plans. Most of the target underdosage corresponded to excessive rectal of bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22 % and 11 % of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety ma

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FD - Oncology and haematology

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Reports of Practical Oncology and Radiotherapy

  • ISSN

    1507-1367

  • e-ISSN

  • Volume of the periodical

    17

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    PL - POLAND

  • Number of pages

    7

  • Pages from-to

    134-140

  • UT code for WoS article

  • EID of the result in the Scopus database