Catheter ablation for atrial fibrillation-Single center experience
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F12%3A10129662" target="_blank" >RIV/00179906:_____/12:10129662 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/12:10129662
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S0010865012001245" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0010865012001245</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2012.11.007" target="_blank" >10.1016/j.crvasa.2012.11.007</a>
Alternative languages
Result language
angličtina
Original language name
Catheter ablation for atrial fibrillation-Single center experience
Original language description
Catheter ablation (CA) has become standard therapy for atrial fibrillation, especially for paroxysmal atrial fibrillation. Precise single center follow-up (FU) data (especially long-term FU data) are published infrequently. Methods: We studied 303 consecutive patients (172 males, 131 females, mean age 57 years) who underwent catheter ablation for atrial fibrillation (489 procedures) in years 2004-2012. Clinical examination, ECG, 24-h or 7-day Holter monitoring and quality of life (QoL) measurement (EQ-5D) was performed at 3, 6, 12, 18 and 24-month FU. Results: FU data longer than 6 month after the first procedure are available for 135 patients with paroxysmal, 84 patients with persistent and 48 patients with longstanding persistent AF. The success rateafter 6 month after the first procedure (sinus rhythm without AA drugs, no arrhythmias) was 48% for paroxysmal, 43% for persistent and 44% for longstanding persistent AF. The complication rate was 3.3% (16 patients, no deaths, no pulmona
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Volume of the periodical
54
Issue of the periodical within the volume
6
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
6
Pages from-to
"e369"-"e374"
UT code for WoS article
—
EID of the result in the Scopus database
—