Detection of EGFR Variants in Plasma A Multilaboratory Comparison of a Real-Time PCR EGFR Mutation Test in Europe
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F18%3A10381923" target="_blank" >RIV/00179906:_____/18:10381923 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.jmoldx.2018.03.006" target="_blank" >https://doi.org/10.1016/j.jmoldx.2018.03.006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmoldx.2018.03.006" target="_blank" >10.1016/j.jmoldx.2018.03.006</a>
Alternative languages
Result language
angličtina
Original language name
Detection of EGFR Variants in Plasma A Multilaboratory Comparison of a Real-Time PCR EGFR Mutation Test in Europe
Original language description
Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of a real-time PCR EGFR mutation test (cobas EGFR Mutation Test v2) to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per milliliter. The circulating tumor DNA was extracted by a cell-free circulating DNA sample preparation kit (cobas cfDNA Sample Preparation Kit), followed by duplicate analysis with the real-time PCR EGFR mutation test (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. All specificities were 98.8% to 100.0%. Coefficients of variation indicated good intralaboratory and interlaboratory repeatability and reproducibility but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the predefined copy number and the observed semiquantitative index values, which reflect the samples' plasma mutation load. This study demonstrates an overall robust performance of the real-time PCR EGFR mutation test kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30109 - Pathology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Molecular Diagnostics
ISSN
1525-1578
e-ISSN
—
Volume of the periodical
20
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
12
Pages from-to
483-494
UT code for WoS article
000438662200010
EID of the result in the Scopus database
2-s2.0-85048978512