Single session of pattern scanning laser versus multiple sessions of conventional laser for panretinal photocoagulation in diabetic retinopathy: Efficacy, safety and painfulness
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F19%3A10399900" target="_blank" >RIV/00179906:_____/19:10399900 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/19:10399900 RIV/00843989:_____/19:E0107864 RIV/61988987:17110/19:A21026ZD
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=LOaani3YSc" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=LOaani3YSc</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0219282" target="_blank" >10.1371/journal.pone.0219282</a>
Alternative languages
Result language
angličtina
Original language name
Single session of pattern scanning laser versus multiple sessions of conventional laser for panretinal photocoagulation in diabetic retinopathy: Efficacy, safety and painfulness
Original language description
Purpose To evaluate the clinical efficiency, safety and painfulness of retinal laser photocoagulation employing a pattern scanning laser system Pascal given in a single-session versus conventional laser multiple-session treatment of the same patient with diabetic retinopathy during 12-month follow-up. Methods The cohort included 60 eyes in 30 patients treated at the Ophthalmology Clinic, Faculty Hospital Ostrava, from 2008 to 2013. Panretinal laser coagulation was performed on one eye using the multispot panretinal photocoagulation given in a single-session system Pascal (OptiMedica, Santa Clara, California). On the other eye laser treatment was carried out by the classic conventional multiple-session method. Results The performance of Pascal panretinal laser coagulation was evaluated as significantly less painful (visual scale of pain was 3.28 +/- 1.9) than the performance of conventional photocoagulation (visual scale of pain was 3.93 +/- 1.88) with similar efficiency. Distribution of progression of diabetic retinopathy in individual patients was very similar in both groups under comparison, and was strictly paired in 24 of the 30 patients at the end of 1-year follow-up. Conclusion Laser photocoagulation of the retina with the use of short impulse durations and patterns in patients with diabetic retinopathy given in one session possesses similar efficiency to that of conventional retinal photocoagulation in multiple sessions. The single session treatment is also better tolerated by patients and in addition to this, it shortens the performance of the whole therapy, which potentially saves considerable funds of all subjects participating in the process of treatment.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30207 - Ophthalmology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
PLoS One
ISSN
1932-6203
e-ISSN
—
Volume of the periodical
14
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
e0219282
UT code for WoS article
000484969300009
EID of the result in the Scopus database
2-s2.0-85069733283