Vena cava filters in patients presenting with major bleeding during anticoagulation for venous thromboembolism
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F19%3A10400440" target="_blank" >RIV/00179906:_____/19:10400440 - isvavai.cz</a>
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=31BZyXHseW" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=31BZyXHseW</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11739-019-02077-5" target="_blank" >10.1007/s11739-019-02077-5</a>
Alternative languages
Result language
angličtina
Original language name
Vena cava filters in patients presenting with major bleeding during anticoagulation for venous thromboembolism
Original language description
The association between inferior vena cava filter (IVC) use and outcome in patients presenting with major bleeding during anticoagulation for venous thromboembolism (VTE) has not been thoroughly investigated. We used the RIETE registry to compare the 30-day outcomes (death, major re-bleeding or VTE recurrences) in VTE patients who bled during the first 3 months of therapy, regarding the insertion of an IVC filter. A propensity score matched (PSM) analysis was performed to adjust for potential confounders. From January 2001 to September 2016, 1065 VTE patients had major bleeding during the first 3 months of anticoagulation (gastrointestinal 370; intracranial 124). Of these, 122 patients (11%) received an IVC filter. Patients receiving a filter restarted anticoagulation later (median, 4 vs. 2 days) and at lower doses (95 +/- 52 IU/kg/day vs. 104 +/- 55 of low-molecular-weight heparin) than those not receiving a filter. During the first 30 days after bleeding (after excluding 246 patients who died within the first 24 h), 283 patients (27%) died, 63 (5.9%) had non-fatal re-bleeding and 19 (1.8%) had recurrent pulmonary embolism (PE). In PSM analysis, patients receiving an IVC filter (n = 122) had a lower risk for all-cause death (HR 0.49; 95% CI 0.31-0.77) or fatal bleeding (HR 0.16; 95% CI 0.07-0.49) and a similar risk for re-bleeding (HR 0.55; 95% CI 0.23-1.40) or PE recurrences (HR 1.57; 95% CI 0.38-6.36) than those not receiving a filter (n = 429). In VTE patients experiencing major bleeding during the first 3 months, use of an IVC filter was associated with reduced mortality rates. Clinical Trial Registration NCT02832245.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Internal and Emergency Medicine
ISSN
1828-0447
e-ISSN
—
Volume of the periodical
14
Issue of the periodical within the volume
7
Country of publishing house
IT - ITALY
Number of pages
12
Pages from-to
1101-1112
UT code for WoS article
000491585400013
EID of the result in the Scopus database
2-s2.0-85065297770