Correlation between end-tidal carbon dioxide and the degree of compression of heart cavities measured by transthoracic echocardiography during cardiopulmonary resuscitation for out-of-hospital cardiac arrest
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F19%3A10402677" target="_blank" >RIV/00179906:_____/19:10402677 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/19:10402677
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=XUOMVNtT1K" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=XUOMVNtT1K</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s13054-019-2607-2" target="_blank" >10.1186/s13054-019-2607-2</a>
Alternative languages
Result language
angličtina
Original language name
Correlation between end-tidal carbon dioxide and the degree of compression of heart cavities measured by transthoracic echocardiography during cardiopulmonary resuscitation for out-of-hospital cardiac arrest
Original language description
Background: The concept of personalized cardiopulmonary resuscitation (CPR) requires a parameter that reflects its hemodynamic efficiency. While intra-arrest ultrasound is increasingly implemented into the advanced life support, we realized a pre-hospital clinical study to evaluate whether the degree of compression of the right ventricle (RV) and left ventricle (LV) induced by chest compressions during CPR for out-of-hospital cardiac arrest (OHCA) and measured by transthoracic echocardiography correlates with the levels of end-tidal carbon dioxide (EtCO2) measured at the time of echocardiographic investigation. Methods: Thirty consecutive patients resuscitated for OHCA were included in the study. Transthoracic echocardiography was performed from a subcostal view during ongoing chest compressions in all of them. This was repeated three times during CPR in each patient, and EtCO2 levels were registered. From each investigation, a video loop was recorded. Afterwards, maximal and minimal diameters of LV and RV were obtained from the recorded loops and the compression index of LV (LVCI) and RV (RVCI) was calculated as (maximal - minimal/maximal diameter) x 100. Maximal compression index (CImax) defined as the value of LVCI or RVCI, whichever was greater was also assessed. Correlations between EtCO2 and LVCI, RVCI, and CImax were expressed as Spearman's correlation coefficient (r). Results: Evaluable echocardiographic records were found in 18 patients, and a total of 52 measurements of all parameters were obtained. Chest compressions induced significant compressions of all observed cardiac cavities (LVCI = 20.6 +/- 13.8%, RVCI = 34.5 +/- 21.6%, CImax = 37.4 +/- 20.2%). We identified positive correlation of EtCO2 with LVCI (r = 0.672, p < 0.001) and RVCI (r = 0.778, p < 0.001). The strongest correlation was between EtCO2 and CImax (r = 0.859, p < 0.001). We identified that a CImax cut-off level of 17.35% predicted to reach an EtCO2 level > 20 mmHg with 100% sensitivity and specificity. Conclusions: Evaluable echocardiographic records were reached in most of the patients. EtCO2 positively correlated with all parameters under consideration, while the strongest correlation was found between CImax and EtCO2. Therefore, CImax is a candidate parameter for the guidance of hemodynamic-directed CPR.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30223 - Anaesthesiology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Critical Care [online]
ISSN
1466-609X
e-ISSN
—
Volume of the periodical
23
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
1-10
UT code for WoS article
000502578000006
EID of the result in the Scopus database
2-s2.0-85074331518