Complex endoleak treatment after failed endovascular aortic repair
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F23%3A10466196" target="_blank" >RIV/00179906:_____/23:10466196 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/23:10466196
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=RISSZ-t36q" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=RISSZ-t36q</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s42155-023-00381-y" target="_blank" >10.1186/s42155-023-00381-y</a>
Alternative languages
Result language
angličtina
Original language name
Complex endoleak treatment after failed endovascular aortic repair
Original language description
Background: Endovascular aneurysm repair (EVAR) has created new possibilities for patients with abdominal aortic aneurysms (AAAs), and in recent years it has become tremendously popular. Use of EVAR in selected groups of patients allows mortality and morbidity to be reduced in comparison to open repair. However, complications such as endoleaks (ELs) can be of great concern and warrant urgent therapy to prevent sac rupture. Case presentation: The case report presents urgent endovascular treatment of a high-risk type IA EL in a polymorbid 68-year-old patient 7 years after primary EVAR. The principle of treatment was parallel implantation of the proximal SG extension with the renal SG into the right renal artery (chimney technique). The subsequent type II collateral EL was treated by direct transabdominal AAA sac puncture and thrombin embolization. Conclusion: EL can be a cause for urgent intervention, but specific anatomic features often require specialized SG types which are not readily available. The chimney technique allows the use of immediately available stent grafts to address endoleak in the setting of impending abdominal aneurysm rupture.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
CVIR Endovascular
ISSN
2520-8934
e-ISSN
2520-8934
Volume of the periodical
6
Issue of the periodical within the volume
1
Country of publishing house
CH - SWITZERLAND
Number of pages
4
Pages from-to
35
UT code for WoS article
001019960900001
EID of the result in the Scopus database
2-s2.0-85164162272