The Role of Digital Facebow for CAD/CAM Implant-Supported Crowns Workflow
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F24%3A10485756" target="_blank" >RIV/00179906:_____/24:10485756 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/24:10485756
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=X_QVqNb~YI" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=X_QVqNb~YI</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14712/18059694.2024.16" target="_blank" >10.14712/18059694.2024.16</a>
Alternative languages
Result language
angličtina
Original language name
The Role of Digital Facebow for CAD/CAM Implant-Supported Crowns Workflow
Original language description
Recent advancements in digital technologies have transformed clinical workflows in dentistry, ensuring precise restorations. Custom-made crowns and fixed partial dentures (FPDs) now rely on virtual articulation. The digital facebow provides individualized data for CAD settings, streamlining the fabrication via digital workflow. For the purpose of demonstrating the differences observed during fabrication, we present a case report involving a 68-year-old patient seeking a replacement for missing teeth 24, 25, 26, and 27. The treatment plan involved the fabrication of an implant-supported FPD using monolithic zirconia (ZrO2). However, technical hurdles emerged during the planning phase, primarily due to spatial limitations posing a risk of mechanical failure over time. Consequently, we pivoted approach towards a porcelain fused to metal (PFM) FPD. For the PFM FPD, individual values from the digital facebow adjusted both virtual and conventional articulators. For comparison, two ZrO2 FPDs were milled-individual settings and average settings. All restorations underwent assessment for occlusion in maximal intercuspal position and eccentric mandible movements. In conclusion, the case report showed that individualized PFM FPD required minimal adjustments compared to milled ZrO2 restorations, whether using individual or average values. Utilizing individual values from the digital facebow reduced operator working time and minimized the intraoral adjustments.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
30208 - Dentistry, oral surgery and medicine
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Medica (Hradec Králové)
ISSN
1211-4286
e-ISSN
1805-9694
Volume of the periodical
67
Issue of the periodical within the volume
1
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
6
Pages from-to
26-31
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85204418427