All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

One-Year Comparison of Efficacy and Safety of PreserFlo MicroShunt with Mitomycin C Applied by Sub-Tenon Injection Versus Sponge

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F25%3A10491256" target="_blank" >RIV/00179906:_____/25:10491256 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11150/25:10491256

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=wLTHDNebVz" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=wLTHDNebVz</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s40123-024-01074-y" target="_blank" >10.1007/s40123-024-01074-y</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    One-Year Comparison of Efficacy and Safety of PreserFlo MicroShunt with Mitomycin C Applied by Sub-Tenon Injection Versus Sponge

  • Original language description

    Introduction: This study was performed to compare the efficacy and safety of PreserFlo MicroShunt (PMS) implantation with mitomycin C (MMC) applied by sub-tenon injection versus conventional application by MMC-soaked sponges. Methods: This retrospective, 1-year cohort study included 100 eyes of 100 patients with glaucoma who underwent PMS implantation with MMC (0.4 mg/ml) delivered either by sub-tenon injection (50 eyes) or via soaked sponges (50 eyes). The primary outcome measure at 1 year was intraocular pressure (IOP) reduction, with complete success defined as an IOP reduction of &gt;= 20% and achieving a target IOP of &lt;= 21 or 18 mmHg without the use of medication. Secondary outcomes, including corneal endothelial cell density (CECD) loss, the number of medications, and complications, were assessed and compared between the groups. Results: Sustained reductions in mean IOP were observed in both groups over the 1-year follow-up, with no significant differences between the groups. The complete success rate, with a target IOP of &lt;= 21 mmHg after 1 year, was 19.3% in the sponge group and 26.4% in the injection group. The qualified success rate was 59.0% and 87.4% in the sponge and injection groups, respectively. A longer survival rate was observed in the injection group than in the sponge group when IOP was below 21 mmHg. The mean CECD significantly decreased (P &lt; 0.01) from baseline to each postoperative follow-up time point in both groups. At 1 year postoperatively, the percentage of total CECD loss was 8.1% in the sponge group and 8.0% in the injection group. However, no significant differences in mean CECD values, the number of medications, or adverse events were found between the groups. Conclusions: PMS implantation with sub-tenon injection of MMC was comparable in terms of efficacy and safety to traditional MMC delivery via soaked sponges. However, the injection group demonstrated a significantly higher success rate than the sponge group.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30207 - Ophthalmology

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Ophthalmology and Therapy

  • ISSN

    2193-8245

  • e-ISSN

    2193-6528

  • Volume of the periodical

    14

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    15

  • Pages from-to

    153-167

  • UT code for WoS article

    001362290600001

  • EID of the result in the Scopus database

    2-s2.0-85210014043