Safety, Adequacy, and Accuracy of Transvaginal Ultrasound-Guided Tru-Cut Biopsy of Gynaecologic Tumours: A Retrospective Single-Centre Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F25%3A10498104" target="_blank" >RIV/00179906:_____/25:10498104 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11150/25:10498104
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=CjTkQztiCs" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=CjTkQztiCs</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics15091133" target="_blank" >10.3390/diagnostics15091133</a>
Alternative languages
Result language
angličtina
Original language name
Safety, Adequacy, and Accuracy of Transvaginal Ultrasound-Guided Tru-Cut Biopsy of Gynaecologic Tumours: A Retrospective Single-Centre Study
Original language description
Objective: To evaluate the safety, adequacy, and accuracy of tru-cut biopsy of gynaecologic tumours in a population of Czech women. Methods: A four-year retrospective study of ultrasound-guided tru-cut biopsy of gynaecologic tumours was conducted in the Department of Obstetrics and Gynaecology, Charles University, Hradec Kralove, Czech Republic. Results: One hundred and four women with gynaecologic tumours underwent transvaginal tru-cut biopsy within the study period. The most common indication for tru-cut biopsy in more than one-half of the women was a suspicion of malignancy/inability to exclude malignancy (59, 56.7%). Most of the tumours were malignant on histopathological examination (71, 68.3%), with advanced ovarian cancer being the most common type of malignancy (43/71, 60.6%). The overall adequacy and accuracy rates of tru-cut biopsy were 93.3% and 93.3%, respectively. Most of the inadequate samples were obtained from overweight and obese women (5/7, 71.4%), with only one biopsy sample taken in the majority of the inadequate biopsies (5/7, 71.4%). Accuracy was higher for malignant than benign tumours (97.7% vs. 82.4%). For malignant tumours, accuracy was highest for advanced ovarian cancers (33/40, 82.5%). Only one case was complicated by bleeding, giving an overall complication rate of 1%. The complicated biopsy was taken by a gynae-oncology trainee. Conclusions: Tru-cut biopsy is a cost-effective and safe preoperative diagnostic modality for patients with gynaecologic tumours, offering high adequacy and accuracy. It is particularly useful in patients with advanced ovarian cancer, most of whom present late with inoperable tumours that contraindicate primary surgery.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30214 - Obstetrics and gynaecology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Diagnostics
ISSN
2075-4418
e-ISSN
2075-4418
Volume of the periodical
15
Issue of the periodical within the volume
9
Country of publishing house
CH - SWITZERLAND
Number of pages
9
Pages from-to
1133
UT code for WoS article
001486403400001
EID of the result in the Scopus database
2-s2.0-105005099729