Implications of Extra-column Effects for Targeted or Untargeted Microflow LC-MS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00179906%3A_____%2F25%3A10499792" target="_blank" >RIV/00179906:_____/25:10499792 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11160/25:10499792
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=R6prtYdox5" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=R6prtYdox5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acsmeasuresciau.5c00015" target="_blank" >10.1021/acsmeasuresciau.5c00015</a>
Alternative languages
Result language
angličtina
Original language name
Implications of Extra-column Effects for Targeted or Untargeted Microflow LC-MS
Original language description
Mass spectrometry (MS) has changed our understanding of health, disease, and the environment through untargeted analyses where entire molecular classes are investigated. These techniques generate huge amounts of data which when processed by statistical tools can identify important molecular features or biomarkers. The complexities of these samples are not compatible with direct introduction to the MS system and require a high-resolution separation step, typically low flow liquid chromatography (LC), prior to MS. LC columns that can produce adequate linear velocities at these low flow rates are small in volume making their results susceptible to resolution loss in extra-column volumes. Here, we investigate the implications of the extra-column effects in five LC-MS systems with triple quadrupole and orbitrap mass analyzers. The extra-column volume of these systems in their standard configuration ranged from 26.4 to 78.1 mu L which we reduced to 9.57 to 18.7 mu L by optimizing the fluidics. The effects of this volume reduction were assessed by studying a hydrolyzed protein sample in a proteomics environment where the intensity of the largest MS peak was improved by 1.8-3.8x. Additionally, the number of molecular features detected in the protein sample improved by up to 7.5x. The relationship between extra-column volumetric variance and flow rate shows that broadening will become much larger for MS detectors at higher flow rates, unlike a traditional small volume UV detector. The methods, applications, and theoretical insights in this work can be used to improve the mass spectrometric results of any LC-MS system.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
ACS Measurement Science au
ISSN
—
e-ISSN
2694-250X
Volume of the periodical
5
Issue of the periodical within the volume
3
Country of publishing house
US - UNITED STATES
Number of pages
13
Pages from-to
332-344
UT code for WoS article
001461930300001
EID of the result in the Scopus database
2-s2.0-105002762947