Quantification of structural changes of UHMWPE components in total joint replacements

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F14%3A10283596" target="_blank" >RIV/00216208:11110/14:10283596 - isvavai.cz</a>

  • Alternative codes found

    RIV/61389013:_____/14:00427703 RIV/00064203:_____/14:10283596

  • Result on the web

    <a href="http://dx.doi.org/10.1186/1471-2474-15-109" target="_blank" >http://dx.doi.org/10.1186/1471-2474-15-109</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1186/1471-2474-15-109" target="_blank" >10.1186/1471-2474-15-109</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Quantification of structural changes of UHMWPE components in total joint replacements

  • Original language description

    At present time the number of implantations of joint replacements as well as their revisions increases. Higher demands are required on the quality and longevity of implants. The aim of this work was to determine the degree of oxidative degradation and the amount of free/residual radicals in selected ultra-high molecular weight polyethylene (UHMWPE) components of the joint replacements and demonstrate that the measured values are closely connected with quality and lifetime of the polymer components. Methods: We tested both new (4 samples) and explanted (4 samples) UHMWPE polymers for total joint replacements. The samples were characterized by infrared spectroscopy (IR), electron spin resonance (ESR) and microhardness (MH) test. The IR measurements yielded the values of oxidation index and trans-vinylene index. The ESR measurements gave the free radicals concentration. Results: In the group of new polyethylene components, we found oxidation index values ranging from 0.00-0.03 to 0.24. Th

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FI - Traumatology and orthopaedics

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    BMC Musculoskeletal Disorders

  • ISSN

    1471-2474

  • e-ISSN

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    March

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    8

  • Pages from-to

  • UT code for WoS article

    000335183900002

  • EID of the result in the Scopus database