Ultrahigh-field MPRAGE Magnetic Resonance Angiography at 7.0 T in patients with cerebrovascular disease
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F15%3A10313935" target="_blank" >RIV/00216208:11110/15:10313935 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/15:10313935
Result on the web
<a href="http://dx.doi.org/10.1016/j.ejrad.2015.09.021" target="_blank" >http://dx.doi.org/10.1016/j.ejrad.2015.09.021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ejrad.2015.09.021" target="_blank" >10.1016/j.ejrad.2015.09.021</a>
Alternative languages
Result language
angličtina
Original language name
Ultrahigh-field MPRAGE Magnetic Resonance Angiography at 7.0 T in patients with cerebrovascular disease
Original language description
Objectives Time-of-flight (TOF) magnetic-resonance-angiography (MRA) identifies vessel pathology in cerebrovascular disease. At 7.0 T, the clinical performance of TOF-MRA is constrained owing to radio frequency power deposition. We studied the diagnosticvalue of whole-brain MPRAGE-based MRA as an alternative imaging technique in comparison to the clinical standard 3.0 T TOF-MRA. Methods Patients with stroke and/or moya-moya disease were included. TOF-MRA was performed at 3.0 T and MPRAGE-MRA at 7.0 T.Two radiologists rated the MRAs independently for overall quality and local arterial segment visualization. The identification of steno-occlusive pathology was reported for each protocol. Results In 18 patients (9 females; 6 patients with moya-moya) 7.0T MPRAGE-MRA provided better overall image quality and better distinction of small structures compared to 3.0 T TOF-MRA. These findings were pronounced in the proximal segments of the anterior cerebral artery (A1), middle cerebral artery
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FH - Neurology, neuro-surgery, nuero-sciences
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Journal of Radiology
ISSN
0720-048X
e-ISSN
—
Volume of the periodical
84
Issue of the periodical within the volume
12
Country of publishing house
IE - IRELAND
Number of pages
5
Pages from-to
2613-2617
UT code for WoS article
000367357700037
EID of the result in the Scopus database
2-s2.0-84949804598