Whole-body low-dose computed tomography in multiple myeloma staging: Superior diagnostic performance in the detection of bone lesions, vertebral compression fractures, rib fractures and extraskeletal findings compared to radiography with similar radiation exposure
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10362239" target="_blank" >RIV/00216208:11110/17:10362239 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/17:10362239 RIV/00159816:_____/17:00068982
Result on the web
<a href="http://dx.doi.org/10.3892/ol.2017.5723" target="_blank" >http://dx.doi.org/10.3892/ol.2017.5723</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3892/ol.2017.5723" target="_blank" >10.3892/ol.2017.5723</a>
Alternative languages
Result language
angličtina
Original language name
Whole-body low-dose computed tomography in multiple myeloma staging: Superior diagnostic performance in the detection of bone lesions, vertebral compression fractures, rib fractures and extraskeletal findings compared to radiography with similar radiation exposure
Original language description
The primary objective of the present prospective study was to compare the diagnostic performance of conventional radiography (CR) and whole-body low-dose computed tomography (WBLDCT) with a comparable radiation dose reconstructed using hybrid iterative reconstruction technique, in terms of the detection of bone lesions, skeletal fractures, vertebral compressions and extraskeletal findings. The secondary objective was to evaluate lesion attenuation in relation to its size. A total of 74 patients underwent same-day skeletal survey by CR and WBLDCT. In CR and WBLDCT, two readers assessed the number of osteolytic lesions at each region and stage according to the International Myeloma Working Group (IMWG) criteria. A single reader additionally assessed extraskeletal findings and their significance, the number of vertebral compressions and bone fractures. The radiation exposure was 2.7 +/- 0.9 mSv for WBLDCT and 2.5 +/- 0.9 mSv for CR (P= 0.054). CR detected bone involvement in 127 out of 486 regions (26%; P< 0.0001), confirmed by WBLDCT. CR underestimated the disease stage in 16% and overestimated it in 8% of the patients (P= 0.0077). WBLDCT detected more rib fractures compared with CR (188 vs. 47; P< 0.0001), vertebral compressions (93 vs. 67; P= 0.010) and extraskeletal findings (194 vs. 52; P< 0.0001). There was no correlation observed between lesion size (>= 5 mm) and its attenuation (r= -0.006; P= 0.93). The inter-observer agreement for the presence of osteolytic lesions was kappa= 0.76 for WBLDCT, and kappa= 0.55 for CR. The present study concluded that WBLDCT with hybrid iterative reconstruction technique demonstrates superiority to CR with an identical radiation dose in the detection of bone lesions, skeletal fractures, vertebral compressions and extraskeletal findings, which results in up-or downstaging in 24% patients according to the IMWG criteria. The attenuation of osteolytic lesions can be measured with the avoidance of the partial volume effect.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Oncology Letters
ISSN
1792-1074
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
4
Country of publishing house
GR - GREECE
Number of pages
5
Pages from-to
2490-2494
UT code for WoS article
000398514200071
EID of the result in the Scopus database
2-s2.0-85015316373