Detection of Microembolic Signals in the Common Carotid Artery Using Doppler Sonography in the Porcine Model of Acute Heart Failure Treated by Veno-Arterial Extracorporeal Membrane Oxygenation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10369385" target="_blank" >RIV/00216208:11110/17:10369385 - isvavai.cz</a>
Alternative codes found
RIV/00064203:_____/17:10369385
Result on the web
<a href="http://www.biomed.cas.cz/physiolres/pdf/66/66_S529.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/66/66_S529.pdf</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Detection of Microembolic Signals in the Common Carotid Artery Using Doppler Sonography in the Porcine Model of Acute Heart Failure Treated by Veno-Arterial Extracorporeal Membrane Oxygenation
Original language description
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30105 - Physiology (including cytology)
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological Research
ISSN
0862-8408
e-ISSN
—
Volume of the periodical
66
Issue of the periodical within the volume
Supplement 4
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
8
Pages from-to
"S529"-"S536"
UT code for WoS article
000422901400011