Femoro-acetabular impingement: anatomic study of reliability and accuracy of alpha angle and offset ratio on fifty consecutive peri-operatively resected femoral heads
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F18%3A10376307" target="_blank" >RIV/00216208:11110/18:10376307 - isvavai.cz</a>
Alternative codes found
RIV/00064211:_____/18:W0000141
Result on the web
<a href="https://doi.org/10.1007/s00264-017-3572-5" target="_blank" >https://doi.org/10.1007/s00264-017-3572-5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00264-017-3572-5" target="_blank" >10.1007/s00264-017-3572-5</a>
Alternative languages
Result language
angličtina
Original language name
Femoro-acetabular impingement: anatomic study of reliability and accuracy of alpha angle and offset ratio on fifty consecutive peri-operatively resected femoral heads
Original language description
Purpose The purpose of this study was to determine whether X-ray attributes of the femoro-acetabular impingement (FAI) - alpha angle (AA) and offset ratio (OR) reflect real measurements on resected femoral heads. Methods FAI AA and OR were assessed on 50 consecutively-resected femoral heads. The parameters were measured on heads cut through the maximum range of the deformity and compared to the same parameters on standardized X-ray projections (anterior-posterior [AP] and axial views). Results Mean AA was 76.47 degrees on dissected heads vs. 75.81 degrees on axial X-ray (p = 0.688). Mean OR was 0.132 on dissected heads vs. 0.220 on axial X-ray (p < 0.001). Mean AA on ideal AP X-ray was 79.46 degrees vs. 81.51 degrees on AP standing plain X-ray view (p = 0.431). AA measurements on plain X-ray AP and axial view of halved femoral heads correlated highly. Conclusions AA on axial X-ray view reflected the real AA in our series, but the risk of cartilage damage cannot be predicted.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Orthopaedics
ISSN
0341-2695
e-ISSN
—
Volume of the periodical
42
Issue of the periodical within the volume
1
Country of publishing house
DE - GERMANY
Number of pages
6
Pages from-to
71-76
UT code for WoS article
000419130000011
EID of the result in the Scopus database
2-s2.0-85025426774