Surgical resection of occluded abdominal stent graft followed by aorto-bi-iliac vascular reconstruction with Intergard Synergy vascular prosthesis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F18%3A10381930" target="_blank" >RIV/00216208:11110/18:10381930 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/18:10381930
Result on the web
<a href="https://doi.org/10.1016/j.crvasa.2017.11.003" target="_blank" >https://doi.org/10.1016/j.crvasa.2017.11.003</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2017.11.003" target="_blank" >10.1016/j.crvasa.2017.11.003</a>
Alternative languages
Result language
angličtina
Original language name
Surgical resection of occluded abdominal stent graft followed by aorto-bi-iliac vascular reconstruction with Intergard Synergy vascular prosthesis
Original language description
Introduction: We are presenting a case report of an 82 years old polymorbid patient treated with Aortofix AAA Flexible Stent Graft System for symptomatic 51 mm subrenal aortic aneurysm complicated with an early closure of the right stent graft branch resulting in a severe right lower extremity ischemia. Method: Stent graft dissection and resection were performed trough midline laparotomy. Due to the severe calcifications of the supra- and sub-renal aorta, a Nucleus 25 mm balloon was inserted into the abdominal aorta instead of using an aortal cross-clamp. After the resection, aorto-bi-iliac revascularisation was performed with the use of Intergard Synergy 18/ 9 mm vascular prosthesis. Result: Following the stent graft resection and surgical revascularisation, normal blood flow was restored into the affected lower extremity with no residual signs and symptoms of limb ischemia. The patient recovered without any further complications and was discharged on the fifth postoperative day. Conclusion: When endovascular treatments of stent grafts' branch occlusion fail, surgical treatment, despite its higher perioperative risks and technical challenges, remains the only treatment option.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Volume of the periodical
60
Issue of the periodical within the volume
5
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
4
Pages from-to
"e547"-"e550"
UT code for WoS article
000446218800025
EID of the result in the Scopus database
2-s2.0-85034853232