Ex vivo models for research in extracorporeal membrane oxygenation: a systematic review of the literature
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10411760" target="_blank" >RIV/00216208:11110/20:10411760 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/20:10411760
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=DJtem1IYjx" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=DJtem1IYjx</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0267659120907439" target="_blank" >10.1177/0267659120907439</a>
Alternative languages
Result language
angličtina
Original language name
Ex vivo models for research in extracorporeal membrane oxygenation: a systematic review of the literature
Original language description
With ongoing progress of components of extracorporeal membrane oxygenation including improvements of oxygenators, pumps, and coating materials, extracorporeal membrane oxygenation became increasingly accepted in the clinical practice. A suitable testing in an adequate setup is essential for the development of new technical aspects. Relevant tests can be conducted in ex vivo models specifically designed to test certain aspects. Different setups have been used in the past for specific research questions. We conducted a systematic literature review of ex vivo models of extracorporeal membrane oxygenation components. MEDLINE and Embase were searched between January 1996 and October 2017. The inclusion criteria were ex vivo models including features of extracorporeal membrane oxygenation technology. The exclusion criteria were clinical studies, abstracts, studies in which the model of extracorporeal membrane oxygenation has been reported previously, and studies not reporting on extracorporeal membrane oxygenation components. A total of 50 studies reporting on different ex vivo extracorporeal membrane oxygenation models have been identified from the literature search. Models have been grouped according to the specific research question they were designed to test for. The groups are focused on oxygenator performance, pump performance, hemostasis, and pharmacokinetics. Pre-clinical testing including use of ex vivo models is an important step in the development and improvement of extracorporeal membrane oxygenation components and materials. Furthermore, ex vivo models offer valuable insights for clinicians to better understand the consequences of choice of components, setup, and management of an extracorporeal membrane oxygenation circuit in any given condition. There is a need to standardize the reporting of pre-clinical studies in this area and to develop best practice in their design.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Perfusion
ISSN
0267-6591
e-ISSN
—
Volume of the periodical
35
Issue of the periodical within the volume
1_suppl
Country of publishing house
GB - UNITED KINGDOM
Number of pages
12
Pages from-to
38-49
UT code for WoS article
000543724600008
EID of the result in the Scopus database