The conversion factor for predicting adenoma detection rate from polyp detection rate varies according to colonoscopy indication and patient sex
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10412791" target="_blank" >RIV/00216208:11110/20:10412791 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/20:00118612 RIV/61383082:_____/20:00000752
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=yySG5TCrMI" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=yySG5TCrMI</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/CEJ.0000000000000558" target="_blank" >10.1097/CEJ.0000000000000558</a>
Alternative languages
Result language
angličtina
Original language name
The conversion factor for predicting adenoma detection rate from polyp detection rate varies according to colonoscopy indication and patient sex
Original language description
The adenoma detection rate (ADR) is the primary quality indicator for colonoscopies. The polyp detection rate (PDR) is available from administrative data and does not depend on histology verification. The correlation between PDR and ADR and the ADR/PDR conversion factor in preventive colonoscopies were evaluated. In the prospective study, asymptomatic individuals aged 45-75 years with preventive colonoscopy in 2012-2016 were included. Spearman's correlation coefficient was used to assess PDR/ADR for each endoscopist. Conversion factor predicting ADR from PDR was obtained by linear regression and subsequently compared with adenoma to polyp detection rate quotient. One thousand six hundred fourteen preventive colonoscopies performed by 16 endoscopists in 8 screening colonoscopy centres in the Czech Republic were analysed. Correlation between PDR and ADR in all preventive colonoscopies was high and statistically significant (Rs 0.82;P< 0.001). There was a strong correlation between PDR and ADR in men (Rs 0.74;P= 0.002) and in screening colonoscopies (Rs 0.85;P< 0.001). The conversion factor to convert ADR from PDR was 0.72 in all preventive colonoscopies, 0.76 in FOBT+ colonoscopies and 0.67 in screening colonoscopies. ADR may be replaced by PDR in the assessment of colonoscopy quality. The value of the conversion factor varies according to colonoscopy indication and gender of examined individuals; in this Czech study, it was 0.72 in all preventive colonoscopies. The minimum requested ADR of 25 % corresponds to a PDR of 35 %, when converted with the appropriate conversion factor.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30219 - Gastroenterology and hepatology
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Journal of Cancer Prevention
ISSN
0959-8278
e-ISSN
—
Volume of the periodical
29
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
294-302
UT code for WoS article
000545919600003
EID of the result in the Scopus database
2-s2.0-85086620187