The Application of Antibacterial Triclosan-Coated Polyglactin 910 Suture versus Conventional Polyglactin 910 Suture in Abdominal Hysterectomy: A Comparison of Selected Postoperative Complications
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10417709" target="_blank" >RIV/00216208:11110/20:10417709 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/20:10417709
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=2C50x3260Y" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=2C50x3260Y</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
The Application of Antibacterial Triclosan-Coated Polyglactin 910 Suture versus Conventional Polyglactin 910 Suture in Abdominal Hysterectomy: A Comparison of Selected Postoperative Complications
Original language description
Background: Abdominal hysterectomy is one of the most frequently performed surgical procedures in gynecology. The new coated polyglactin 910 sutures with the antibacterial agent triclosan may help to reduce the frequency of infectious postoperative complications and consequently shorten the duration of hospital stay. Materials and methods: The study was carried out with 450 patients who underwent abdominal hysterectomy between August 2008 and August 2018. The following factors were taken into account: C-reactive protein, the application of post-operative antibiotics, the maximum body temperature, the duration and the cost of hospitalization. Results: In those cases where triclosan-coated suture was used, the phlogistic C-reactive marker was significantly lower (p < 0.002) than in the group where conventional suture without triclosan was used, the maximum body temperature during the whole period of hospitalization was also significantly lower (p = 0.004), the application of post-operative antibiotics was significantly lower (p < 0.001), the length of hospital stay was significantly shorter (p < 0.001), and the costs, calculated in treatment days, were also significantly lower (p < 0.001). Conclusions: It can be concluded that the application of the sutural material with triclosan offers real benefits in the prevention of infectious complications. Particularly, the vaginal wound is the region with the highest colonization of pathogens. Therefore, for the suture of the vaginal wound in particular, we especially recommend applying triclosan-coated polyglactin 910 suture in order to eliminate the risk of local infection resulting directly from the use of the sutural material.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30214 - Obstetrics and gynaecology
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Aktuální gynekologie a porodnictví
ISSN
1803-9588
e-ISSN
—
Volume of the periodical
12
Issue of the periodical within the volume
listopad
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
5
Pages from-to
65-69
UT code for WoS article
000596016200001
EID of the result in the Scopus database
—