All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Assessing the Accuracy of Bed-Occupancy With a tina.care Bed Sensor in Hospital Wards and Home Care Settings: A Pilot Study

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F25%3A10498368" target="_blank" >RIV/00216208:11110/25:10498368 - isvavai.cz</a>

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=RhYx0PfMPo" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=RhYx0PfMPo</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/OJEMB.2025.3548838" target="_blank" >10.1109/OJEMB.2025.3548838</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Assessing the Accuracy of Bed-Occupancy With a tina.care Bed Sensor in Hospital Wards and Home Care Settings: A Pilot Study

  • Original language description

    Goal: This pilot study aims to assess accuracy in detecting patient presence or absence by using a bed sensor based on mmwave radar technology above the patient bed. Methods: Patients and healthy volunteers were observed during their presence or absence in a bed in hospital and home location. These observations were compared with data coming from bed sensor monitoring patient presence using tina.care bed sensor ASWA. Results: A total of 53 different observations were performed during the study period and the bed sensor reached accuracy of 94%, precision of 90%, sensitivity of 99% and specificity of 89% to detect presence or absence of patients in a bed. Conclusions: The sensor demonstrated strong performance in detecting patient presence in bed, with reasonable specificity and low false negatives. Further research should assess bed-exit and bed-entry events, system&apos;s accuracy in a larger cohort, its impact on patient care, and the precision of vital health parameters measured by the sensor in order to compare it with similar studies.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30502 - Other medical science

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    IEEE Open Journal of Engineering in Medicine and Biology

  • ISSN

    2644-1276

  • e-ISSN

    2644-1276

  • Volume of the periodical

    6

  • Issue of the periodical within the volume

    March

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    5

  • Pages from-to

    420-424

  • UT code for WoS article

    001470318500001

  • EID of the result in the Scopus database

    2-s2.0-105003661068