All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

In vitro coronary stent implantation: Vessel wall-stent interaction

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F12%3A00003227" target="_blank" >RIV/00216208:11120/12:00003227 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/978-3-642-23508-5_207" target="_blank" >http://dx.doi.org/10.1007/978-3-642-23508-5_207</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-3-642-23508-5_207" target="_blank" >10.1007/978-3-642-23508-5_207</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    In vitro coronary stent implantation: Vessel wall-stent interaction

  • Original language description

    This study was designed to assess the biomechanical interactions between the coronary artery wall and intracoronary stents following implantation in vitro. Balloon expandable stent was deployed in vitro into the sample of the left anterior descending coronary artery of a 67 years old female with multiple atherosclerotic lesions. The stent was selected to match approximately the internal diameter of the healthy segment of the target artery. The stent implantation procedure was recorded with CCD camera. Digital images were subsequently processed with the edge detector based on Canny algorithm. Obtained coordinates of the surface contours were used in the deformation analysis. For the sake of simplicity the deformation was considered as the ratio betweenthe distances of deformed and reference contour points at the same longitudinal position. We found that the stent expansion induced significant over-stretching of the external coronary artery. We have concluded that optical tracking of th

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JJ - Other materials

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GA106%2F08%2F0557" target="_blank" >GA106/08/0557: Material properties of veins and their remodelling</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    5th European Conference of the International Federation for Medical and Biological Engineering

  • ISBN

    978-3-642-23508-5

  • ISSN

    1680-0737

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    795-798

  • Publisher name

    Springer Medizin Verlag

  • Place of publication

    Heidelberg

  • Event location

    Budapest

  • Event date

    Sep 14, 2011

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000310938200207