Long-term outcomes of patients receiving zotarolimus-eluting stents in ST elevation myocardial infarction, non-ST elevation acute coronary syndrome, and stable angina: Data from the Resolute program
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F13%3A43907504" target="_blank" >RIV/00216208:11120/13:43907504 - isvavai.cz</a>
Alternative codes found
RIV/00064173:_____/13:N0000003
Result on the web
<a href="http://dx.doi.org/10.1016/j.ijcard.2013.04.209" target="_blank" >http://dx.doi.org/10.1016/j.ijcard.2013.04.209</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijcard.2013.04.209" target="_blank" >10.1016/j.ijcard.2013.04.209</a>
Alternative languages
Result language
angličtina
Original language name
Long-term outcomes of patients receiving zotarolimus-eluting stents in ST elevation myocardial infarction, non-ST elevation acute coronary syndrome, and stable angina: Data from the Resolute program
Original language description
Outcome data are limited in patients with ST-segment elevation acute myocardial infarction (STEMI) or other acute coronary syndromes (ACSs) who receive a drug-eluting stent (DES). Data suggest that first generation DES is associated with an increased risk of stent thrombosis when used in STEMI. Whether this observation persists with newer generation DES is unknown. The study objective was to analyze the two-year safety and effectiveness of Resolute zotarolimus-eluting stents (R-ZESs) implanted for STEMI, ACS without ST segment elevation (non-STEACS), and stable angina (SA). METHODS: Data from the Resolute program (Resolute All Comers and Resolute International) were pooled and patients with R-ZES implantation were categorized by indication: STEMI (n=335), non-STEACS (n=1416), and SA (n=1260). CONCLUSION: R-ZES in STEMI and in other clinical presentations is effective and safe. Long term outcomes are favorable with an extremely rare incidence of late and very late stent thrombosis follo
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Cardiology
ISSN
0167-5273
e-ISSN
—
Volume of the periodical
168
Issue of the periodical within the volume
4
Country of publishing house
IE - IRELAND
Number of pages
5
Pages from-to
3522-3526
UT code for WoS article
000326219600062
EID of the result in the Scopus database
—