The Insufficiency of Left Anterior Oblique and the Usefulness of Right Anterior Oblique Projection for Correct Localization of a Computed Tomography-Verified Right Ventricular Lead Into the Midseptum
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F13%3A43907540" target="_blank" >RIV/00216208:11120/13:43907540 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1161/CIRCEP.113.000232" target="_blank" >http://dx.doi.org/10.1161/CIRCEP.113.000232</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1161/CIRCEP.113.000232" target="_blank" >10.1161/CIRCEP.113.000232</a>
Alternative languages
Result language
angličtina
Original language name
The Insufficiency of Left Anterior Oblique and the Usefulness of Right Anterior Oblique Projection for Correct Localization of a Computed Tomography-Verified Right Ventricular Lead Into the Midseptum
Original language description
The aim of the study was to verify the correct anchoring location for the tip of the right ventricular lead using cardiac computed tomography and to assess the best fluoroscopic and ECG criteria associated with the correct location of the electrode intothe midseptum. Methods and Results-Patients indicated to pacemaker implantation were prospectively enrolled. The right ventricular lead was implanted into the midseptum according to standard criteria in left anterior oblique 40 view. The cardiac shadow on the right anterior oblique 30 was divided into 4 quadrants perpendicular to the lateral cardiac silhouette and the position of the lead tip was analyzed. The exact position of the lead tip was assessed using computed tomography. Of 51 patients, the right ventricular lead was anchored midseptum in 21 (41.2%; MS group). In 30 patients (58.8%; non-MS group), the lead was anchored in the adjacent anterior wall. The angle between the lead and horizontal axis on the left anterior oblique was
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Circulation-Arrhythmia and Electrophysiology
ISSN
1941-3149
e-ISSN
—
Volume of the periodical
6
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
7
Pages from-to
719-725
UT code for WoS article
000323323900020
EID of the result in the Scopus database
—