Mathematical modelling for the comparison of plate and intramedullary osteosynthesis stability in intraarticular distal radius fractures

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F14%3A43908108" target="_blank" >RIV/00216208:11120/14:43908108 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21220/14:00218091 RIV/00216208:11110/14:10195720 RIV/00216208:11130/14:10195720 RIV/00064203:_____/14:10195720

  • Result on the web

    <a href="http://dx.doi.org/10.4149/BLL_2014_023" target="_blank" >http://dx.doi.org/10.4149/BLL_2014_023</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.4149/BLL_2014_023" target="_blank" >10.4149/BLL_2014_023</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Mathematical modelling for the comparison of plate and intramedullary osteosynthesis stability in intraarticular distal radius fractures

  • Original language description

    Background: A comparison between plate and intramedullary osteosynthesis techniques in terms of the biomechanical stability of distal radius fracture fixation. Methods: Mathematical modelling was used to simulate distal radius fractures, type C1 and typeC2, and to compare the stability of osteosynthesis in both techniques under several wrist joint load conditions: axial compressive loading of the radius, bending loads in volar and dorsal flexion and radial and ulnar deviation, and axial torsional loading of the forearm. Results: For both type C1 and type C2 fractures, the stability of intramedullary osteosynthesis was comparable with plate osteosynthesis in dorsal flexion. Plate osteosynthesis proved to be more stable only in ulnar deviation. The intramedullary X-screw technique provided more stability when loads were applied in volar flexion, radial deviation, pronation and supination, and in axial loading of the radius. Conclusions: The result of mathematical simulations was compara

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FI - Traumatology and orthopaedics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Bratislavské lekárske listy

  • ISSN

    0006-9248

  • e-ISSN

  • Volume of the periodical

    115

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    SK - SLOVAKIA

  • Number of pages

    5

  • Pages from-to

    107-111

  • UT code for WoS article

    000331992300012

  • EID of the result in the Scopus database