Clinical results with the Resolute zotarolimus-eluting stent in total coronary occlusions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F15%3A43909181" target="_blank" >RIV/00216208:11120/15:43909181 - isvavai.cz</a>
Alternative codes found
RIV/00064173:_____/15:N0000001
Result on the web
<a href="http://dx.doi.org/10.4244/eijy14m07_14" target="_blank" >http://dx.doi.org/10.4244/eijy14m07_14</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4244/eijy14m07_14" target="_blank" >10.4244/eijy14m07_14</a>
Alternative languages
Result language
angličtina
Original language name
Clinical results with the Resolute zotarolimus-eluting stent in total coronary occlusions
Original language description
Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute(R) zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and results: Patients were divided into three groups: chronic TO (CTO; n=256), non-chronic TO (n=292), and no occlusion (n=2,941). Clinical and safety outcomes assessed through two years included target lesion failure(TLF: cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
EuroIntervention
ISSN
1774-024X
e-ISSN
—
Volume of the periodical
11
Issue of the periodical within the volume
6
Country of publishing house
FR - FRANCE
Number of pages
8
Pages from-to
650-657