Double-gap-in-roof reentrant tachycardia following surgical thoracoscopic atrial fibrillation ablation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F15%3A43910802" target="_blank" >RIV/00216208:11120/15:43910802 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.ipej.2015.09.008" target="_blank" >http://dx.doi.org/10.1016/j.ipej.2015.09.008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ipej.2015.09.008" target="_blank" >10.1016/j.ipej.2015.09.008</a>
Alternative languages
Result language
angličtina
Original language name
Double-gap-in-roof reentrant tachycardia following surgical thoracoscopic atrial fibrillation ablation
Original language description
A case of macro-reentrant tachycardia associated with a box lesion after thoracoscopis left atrial surgical atrial fibrillation (AF) ablation yet to be described. The goal was to clarify the mechanisms and electrophysiological characteristics of this type of tachycardia. A patient was admitted for an EP study following surgical thoracoscopic AF ablation (box lexion formation by right-sided Cobra thoracoscopic ablation). Thoracoscopic ablation was done as the first step of the hybrid ablation approach tothe persistent AF; the second step was the EP study. At the EP study, he presented with incessant regular tachycardia (cycle length of 226 ms). An EP study with conventional, 3D activation and entrainment mapping was done to assess the tachycardia mechanism. Two conduction gaps in the superior line (roofline) between the superior pulmonary veins were discovered. The tachycardia was successfully treated with a radiofrequency application near the gap close to the left superior pulmonary v
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Indian Pacing and Electrophysiology Journal
ISSN
0972-6292
e-ISSN
—
Volume of the periodical
15
Issue of the periodical within the volume
3
Country of publishing house
IN - INDIA
Number of pages
5
Pages from-to
172-176
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-84949512215