Manual aspiration thrombectomy devices use in coronary interventions in 2016
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F16%3A43910962" target="_blank" >RIV/00216208:11120/16:43910962 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1586/17434440.2016.1146586" target="_blank" >http://dx.doi.org/10.1586/17434440.2016.1146586</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1586/17434440.2016.1146586" target="_blank" >10.1586/17434440.2016.1146586</a>
Alternative languages
Result language
angličtina
Original language name
Manual aspiration thrombectomy devices use in coronary interventions in 2016
Original language description
Percutaneous coronary intervention is a highly effective therapy of acute myocardial infarction. Restoration of microcirculation is however often sub-optimal with negative impact on patient outcome. Distal thrombus embolization may contribute to this issue. Simple manual aspiration thrombectomy catheters were developed with aim of thrombus extraction. There are several of these devices with very similar design. Thrombotic or atheromatous tissue is successfully retrieved in over 70% of patients. The initial results of small, often single center studies have provided encouraging results. Unfortunately, three further studies clearly demonstrated lack of any clinical benefit and routine use of manual aspiration thrombectomy cannot be recommended. Small but statistically significant increase in stroke rate is the major safety issue. Selective use in patients with large thrombus burden or suboptimal flow or perfusion is likely to continue and needs to be scientifically studied.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Expert Review of Medical Devices
ISSN
1743-4440
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
3
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
243-251
UT code for WoS article
000370830400003
EID of the result in the Scopus database
2-s2.0-84959324139