Evaluation of low-intensity anti-coagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F18%3A43916579" target="_blank" >RIV/00216208:11120/18:43916579 - isvavai.cz</a>
Alternative codes found
RIV/00023001:_____/18:00076888
Result on the web
<a href="https://doi.org/10.1016/j.healun.2018.03.002" target="_blank" >https://doi.org/10.1016/j.healun.2018.03.002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.healun.2018.03.002" target="_blank" >10.1016/j.healun.2018.03.002</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of low-intensity anti-coagulation with a fully magnetically levitated centrifugal-flow circulatory pump-the MAGENTUM 1 study
Original language description
Background: The HeartMate 3 left ventricular assist system is engineered to avoid pump thrombosis, yet bleeding complications persist. We investigated the safety of low-intensity anti-coagulation in patients with the HeartMate 3. Methods: The Minimal AnticoaGulation EvaluatioN To aUgment heMocompatibility (MAGENTUM 1) pilot study is a prospective, single-arm study of low-intensity warfarin anti-coagulation in patients implanted with the HeartMate 3 pump. After standard warfarin anti-coagulation (international normalized ratio [INR] 2.0 to 3.0) and aspirin for 6 weeks post-implant, patients were transitioned to a lower INR target range of 1.5 to 1.9. The primary end-point was a composite of survival free of pump thrombosis, disabling stroke (modified Rankin score [MRS] >3), or major bleeding (excluding peri-operative bleeding) with at least 6-month post-implant follow-up. Time in therapeutic range (TTR) was measured to assess anti-coagulation target efficacy using the Rosendaal method. A safety algorithm to monitor for signs of pump thrombosis was developed and implemented. Results: We enrolled 15 patients (mean age 57.3 +- 13.3 years), 13 men with advanced heart failure (67% with INTERMACS Profiles 2 or 3), irrespective of therapeutic goal of bridge-to-transplant or destination therapy. The primary end-point was met in 14 of 15 (93 +- 6%) patients; 1 patient developed recurrent gastrointestinal bleeding. The TTR during the reduced anti-coagulation phase (6 weeks to 6 months) was 75.2 +- 8.6%. No thrombotic events occurred. Conclusions: This pilot study suggests low-intensity anti-coagulation targeting an INR between 1.5 and 1.9 is achievable and safe with the HeartMate 3 cardiac pump in the short-term phase, 6-months post-implant. A large-scale trial is now warranted.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
The Journal of Heart and Lung Transplantation
ISSN
1053-2498
e-ISSN
—
Volume of the periodical
37
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
579-586
UT code for WoS article
000432164900009