All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Direct sample injection from a syringe needle into a separation capillary

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F18%3A43916921" target="_blank" >RIV/00216208:11120/18:43916921 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11310/18:10382492

  • Result on the web

    <a href="https://doi.org/10.1016/j.aca.2018.07.026" target="_blank" >https://doi.org/10.1016/j.aca.2018.07.026</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.aca.2018.07.026" target="_blank" >10.1016/j.aca.2018.07.026</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Direct sample injection from a syringe needle into a separation capillary

  • Original language description

    An automatic micro-injector was developed for electrophoretic analysis of a microlitre amount of clinical samples, enabling injection of the sample from a Hamilton syringe. The outlet of the syringe needle is located directly opposite the inlet of the separation capillary at a defined distance of the order of hundreds of μm in the injection space. During the injection, the background electrolyte is forced out by air from this space and a drop of the sample is forced out of the syringe by a micro-pump so that it is caught at the entrance to the capillary. From the drop the sample is injected into the capillary by applying a negative pressure pulse or simply by spontaneous injection. The injection space is then filled with background electrolyte, which washes away excess sample and separation is commenced. The injector was tested in electrophoretic separation of a model sample with equimolar concentrations of 100 μM NH4 +, K+, Na+, Mg2+ and Li+ in a short capillary with total/effective length of 16.5/11.5 cm. The repeatability of the migration time and peak area expressed as the RSD value is 2% and 4%, respectively. The practical applicability of the injector was verified on the determination of the antiparasitic pentamidine in 10 μL of rat plasma. Electrophoretic separation of pentamidine was performed in 100 mM of acetic acid/NaOH at pH 4.55, the sample consumption per analysis is 125 nL, the separation time is 45 s and the attained LOQ using contactless conductivity detection is 8 μM.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA15-03139S" target="_blank" >GA15-03139S: New Electrophoretic Approaches in Studies of Obesity and Diabetes</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytica Chimica Acta

  • ISSN

    0003-2670

  • e-ISSN

  • Volume of the periodical

    1042

  • Issue of the periodical within the volume

    December

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    8

  • Pages from-to

    133-140

  • UT code for WoS article

    000448290800016

  • EID of the result in the Scopus database

    2-s2.0-85049915456